Pulse amplifier
|
|
Slot initiator
|
Sensor SJ 3,5-N-K37
|
|
Power supply (from SITRANS F RA110)
|
8 V DC, Ri approx. 1 k? (DIN 19234) Ci = 40 nF; Li = 160 µH
|
|
Change in current consumption on pulse
|
? 1 mA/ ? 3mA (DIN 19234)
|
|
Permissible line resistance between pick-up and amplifier
|
? 50 ? (DIN 19234)
|
|
Number of pulses per revolution of the drive
|
10 or 100
|
|
Phase position of the channels of the double pick-up
|
180 ° : 180 ° ± 30 ° Electrically offset 90 ° ± 30 °
|
|
Duty factor
|
1 : 1 ± 17 %
|
|
Max. pulse frequency
|
3 000 Hz
|
|
Pulse valence
|
Dependent on value per revolution of the drive of the respective meter
|
|
Permissible ambient temp.
|
-25 ... +100 °C (-13 ... +212 °F)
|
|
Degree of protection
|
IP43 to EN 60529 with register
|
| |
P65 to EN 60529 with protective cover
|
| |
This pulser has the EC-Type Examination Certificate PTB 99 ATEX 2219X.
|
|
Mounting position
|
Any
|
|
Weight approx.
|
1.2 kg (2.65 lb)
|
|
Ex approval
|
IIG EEx ia IIC T6
|