SITRANS P pressure transmitters, MPS series (submersible sensor)
|
|
Mode of operation
|
|
|
Measuring principle
|
piezo-resistive
|
|
Input
|
|
|
Measured variable
|
Hydrostatic level
|
|
Measuring range
|
Maximum operating pressure
|
- 0 ... 2 mH2O (0 ... 6 ftH2O)
|
- 1.4 bar (20.3 psi) (corresponds to 14 mH2O (42 ftH2O))
|
- 0 ... 4 mH2O (0 ... 12 ftH2O)
|
- 1.4 bar (20.3 psi) (corresponds to 14 mH2O (42 ftH2O))
|
- 0 ... 5 mH2O (0 ... 15 ftH2O)
|
- 1.4 bar (20.3 psi) (corresponds to 14 mH2O (42 ftH2O))
|
- 0 ... 6 mH2O (0 ... 18 ftH2O)
|
- 3.0 bar (43.5 psi) (corresponds to 30 mH2O (90 ftH2O))
|
- 0 ... 10 mH2O ( ... 30 ftH2O)
|
- 3.0 bar (43.5 psi) (corresponds to 30 mH2O (90 ftH2O))
|
- 0 ... 20 mH2O (0 ... 60 ftH2O)
|
- 6.0 bar (87.0 psi) (corresponds to 60 mH2O (180 ftH2O))
|
|
Output
|
|
|
Output signal
|
4 ... 20 mA
|
|
Measuring accuracy
|
Acc. to EN 60770-1
|
|
Error in measurement (including non-linearity, hysteresis and repeatability, at 25 °C (77 °F))
|
0.3% of full-scale value (typical)
|
|
Influence of ambient temperature
|
|
|
Zero and span
|
|
- 1 ... 6 mH2O (3 ... 18 ftH2O)
|
0.45 %/10 K of full-scale value
|
|
|
0.3 %/10 K of full-scale value
|
|
Long-term stability
|
|
|
Zero and span
|
|
- 1 ... 6 mH2O (3 ...18 ftH2O)
|
0.25 % of full-scale value/year
|
|
|
0.2 % of full-scale value/year
|
|
Rated conditions
|
|
|
Ambient conditions
|
|
|
|
-10 ... +80 °C (+14 ... +176 °F)
|
|
|
-40 ... +100 °C (-40 ... +212 °F)
|
|
Degree of protection to DIN EN 60529
|
IP68
|
|
Design
|
|
|
Weight
|
|
|
|
≈ 0.4 kg (≈ 0.88 lb)
|
|
|
0.08 kg/m (≈ 0.054 lb/ft)
|
|
Electrical connection
|
Cable with 2 conductors with screen and vent pipe, strength cord (max. 300 N (67.44 lbf)
|
|
Material
|
|
|
|
Stainless steel, mat. No. 316L/316 Ti
|
|
|
Stainless steel, mat. No. 316L/316 Ti
|
|
|
Viton
|
|
|
Either PE/HFFR sheath (non-halogen) or FEP sheath
|
|
Auxiliary power
|
|
|
Terminal voltage on pressure transmitter UB
|
10 ... 36 V DC
|
|
Certificates and approvals
|
|
|
The transmitter is not subject to the pressure equipment directive (PED 97/23/EC)
|
|
Explosion protection
|
|
|
|
TÜV 03 ATEX 2004X
|
|
|
Ex II 1 G EEx ia IIC T4
|