Pressure transmitters for food, pharmaceuticals and biotechnology
|
|
Mode of operation
|
|
|
Measuring principle
|
Piezo-resistive
|
|
Input
|
|
|
Measured variable
|
Gage or absolute pressure
|
|
Measuring range
|
0 ... 160 mbar (0 ... 2.32 psi) ... 0 ... 40 bar (0 ... 580 psi)
|
|
Output
|
|
|
Output signal
|
|
|
|
4 ... 20 mA
|
|
|
0 ... 20 mA
|
|
Measuring accuracy
|
to EN 60770-1
|
|
Linearity error including hysteresis (reference point adjustment)
|
= 0.2 % of full-scale value
|
|
Adjustment accuracy
|
= ± 0.2 % of full-scale value
|
|
Response time
|
< 20 ms
|
|
Influence of ambient temperature
|
|
|
On the enclosure
|
|
|
|
< 0.2 %/10 K of full-scale value
|
|
|
< 0.2 %/10 K of full-scale value
|
|
On the process connection (remote seals)
|
Zero error (depends on design)
|
|
|
|
|
|
4.8 mbar/10 K (0.070 psi/10 K)
|
|
|
2.3 mbar/10 K (0.033 psi/10 K)
|
|
|
1.6 mbar/10 K (0.023 psi/10 K)
|
|
|
0.6 mbar/10 K (0.009 psi/10 K)
|
|
|
|
|
|
9.5 mbar/10 K (0.138 psi/10 K)
|
|
|
4.1 mbar/10 K (0.060 psi/10 K)
|
|
|
3.9 mbar/10 K (0.057 psi/10 K)
|
|
|
3.9 mbar/10 K (0.057 psi/10 K)
|
|
The zero error specified for the process connection should be considered as a guideline for a standard design. We will produce a detailed system calculation on request. Systems with reduced remote seal errors are available on request.
|
|
Rated conditions
|
|
|
Installation conditions
|
|
|
|
Any, vertical as standard
|
|
Ambient conditions
|
|
|
|
-10 ... +70 °C (14 ... 158 °F)
|
|
|
-10 ... +90 °C (14 ... 194 °F)
|
|
|
Max. 200 °C (392 °F), depending on design
|
- Degree of protection (to EN 60529)
|
IP65, optional IP67
|
- Electromagnetic compatibility
|
|
|
|
To EN 50081 Part 1, issue 1993 (residential and industrial areas). The unit has no own emissions.
|
|
|
EN 50082 Part 2, issue March 1995 (industrial areas)
|
|
Construction
|
|
|
Weight (without remote seal)
|
|
|
|
˜ 460 g (˜ 1.01 lb)
|
|
|
˜ 200 g (˜ 0.44 lb)
|
|
Enclosure
|
|
|
|
- Field housing IP65 or IP67, with screwed gland
- Angled plug DIN 43650, IP65
- Cable connection, IP67
- Round plug connector M12, IP65
|
|
|
Stainless steel, mat. No. 1.4404/316L/1.4305
|
|
Material of union nut
|
Polyamide (with electrical connection using plug or cable)
Electronics unit potted with silicone
Internal ventilation for measuring ranges < 16 bar (< 232 psi), through housing thread or connecting cable depending on design
|
|
Process connection
|
|
|
|
See ordering data
|
|
|
Stainless steel, mat. No. 1.4404/316L
|
|
Power supply
|
|
|
Terminal voltage on transmitter
|
10 ... 30 V DC
|
|
Rated voltage
|
24 V DC
|
|
Certificates and approvals
|
|
|
Classification according to pressure equipment directive (DRGL 97/23/EC)
|
For gases of fluid group 1 and liquids of fluid group 1; complies with the requirements of Article 3, paragraph 1 (appendix 1); assigned to category III, conformity evaluation module H by the TÜV Nord
|
|
Explosion protection
|
|
|
|
TÜV 03 ATEX 2099 X
|
|
|
Ex II 2G EEx ib IIC T6
|