6GK1704-1CW12-0AA0Цена на сайте указана розничная в ЕВРО без учета НДС. Для уточнения цены и размера предоставляемой скидки - звоните или присылайте заявки | Заказной номер | Вес | PG | Описание продукта | Цена | | 6GK1704-1CW12-0AA0 | 0.33 | 5S1 | ПО SIMATIC NET IE SOFTNET-S7 V12 Включая S7, S5 - ОРС, PG/OP ПРОГРАММНОЕ ОБЕСПЕЧЕНИЕ до 64 соед. ДОКУМЕНТ. НА DVD; КЛЮЧ ЛИЦЕНЗИИ НА USB-носителе; | По запросу |
п»ї - Connection of SIMATICВ S7-300/SINUMERIK 840D powerline to Industrial Ethernet
- 2 x RJ45 interface for 10/100 Mbps full/half-duplex connection with autosensing/autonegotiation and autocrossover function
- Integrated 2-port real-time switch ERTEC
- Multi-protocol operation with ISO, TCP, UDP transport protocol and PROFINET IO
- Adjustable keep-alive function
- Communications services:
- Open communication (ISO, TCP/IP, and UDP)
- PROFINET IO controller or PROFINET IO device
- PG/OP communication: Cross-network by means of S7 routing
- S7 communication (client, server, multiplexing)
- Media redundancy (MRP);
within an Ethernet network with ring topology, the CP supports the media redundancy procedure MRP (V2.2 or higher). - Multicast for UDP
- IP address assignment via DHCP, simple PC tool or via the user program (e.g. HMI)
- Access protection via configurable access list
- Remote programming and commissioning via Industrial Ethernet
- Configuration with STEP 7
- Automatic setting of CPU clock setting over Ethernet with NTP or SIMATIC procedure
- Web diagnostics
- Integration in network management systems via SNMP (MIB2 diagnostics information)
- Diagnostics possibilities in STEP 7 and via web browser
Note:SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were taken from the respective standard products. SIPLUSВ extreme-specific information was added. SIPLUS CP 343-1 | В |
|---|
Article No. | 6AG1343-1EX30-7XE0 | BasedOn Article No. | 6GK7343-1EX30-0XE0 | Ambient temperature range | -25В ...В +70В В°C; 60 В°C @ UL/cUL, ATEX and FM use | Conformal coating | Coating of the printed circuit boards and the electronic components | Technical data | The technical data of the standard product applies except for the ambient conditions. | Ambient conditions | Relative humidity | 100%, condensation/frost permissible. No commissioning if condensation present. | Biologically active substances, compliance with EN 60721-3-3 | Class 3B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation! | Chemically active substances, compliance with EN 60721-3-3 | Class 3C4 incl. salt spray in accordance with EN60068-2-52 (degree of severity 3). The supplied plug covers must remain in place over the unused interfaces during operation! | Mechanically active substances, compliance with EN 60721-3-3 | Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation! | Air pressure (depending on the highest positive temperature range specified) | 1В 080В ...В 795В hPa (-1В 000В ...В +2В 000В m) see ambient temperature range 795В ...В 658В hPa (+2В 000В ...В +3В 500 m) derating 10В K 658В ...В 540В hPa (+3В 500В ...В +5В 000В m) derating 20В K |
For further technical documentation on SIPLUS, see: http://www.siemens.com/siplus-extreme
|
|