3VL3720-3DC36-....Цена на сайте указана розничная в ЕВРО без учета НДС. Для уточнения цены и размера предоставляемой скидки - звоните или присылайте заявки | Заказной номер | Вес | PG | Описание продукта | Цена | | 3VL3720-3DC36-.... | 2.3 | | АВТОМАТИЧЕСКИЙ ВЫКЛЮЧАТЕЛЬ VL 250L ОЧЕНЬ ВЫСОКАЯ ОТКЛЮЧАЮЩАЯ СПОСОБНОСТЬ ICU=100KA/415 V AC 3-ПОЛЮСА, ЗАЩИТА УСТАНОВОК, РАСЦЕПИТЕЛЬ МАКСИМАЛЬНОГО ТОКА TM, LI IN=200A, НОМИНАЛЬНЫЙ ТОК IR=160-200A, ПЕРЕГРУЗКА II=1000-2000A, К.З. | По запросу |
п»їSelection and ordering dataThe following table lists recommendations for additional line-side components, such as fuses and circuit breakers. Note for use in compliance with IEC standards: Type 3NA3 fuses and type 3RV circuit breakers are recommended for European countries. The values in the table take into account the overload capability of the inverter. Notes for use in compliance with UL regulations: Fuses for use in North America must be UL-certified, class J, T, CC, G or CF fuses with a rated voltage of 600В VВ AC. Short Circuit Current Rating (SCCR) according to UL Applies to industrial control panel installations to NEC Article 409 or UL 508A. - SINAMICSВ G120C: 100В kA (the value depends on the fuses and circuit breakers used)
Notes regarding installations in Canada: Overvoltage protection devices in accordance with overvoltage categoryВ III and with the following ratings must be connected on the line side of the inverter: - Rated voltage 480В V (phase-phase) and 480В V (phase-ground)
- Voltage limit 4В kV (phase-phase) and 6В kV (phase-ground)
All overvoltage protection devices used must comply with Canadian standards for industrial installations. Further information, particularly regarding use in accordance with UL guidelines, is available at https://support.industry.siemens.com/cs/document/109478990 Additional information about the listed fuses and circuit breakers is available in the Catalogs LVВ 10, ICВ 10 and ICВ 10В AO as well as in the Industry Mall. Rated power | SINAMICSВ G120C | IEC-compliant | UL/cUL-compliant |
|---|
В | В | В | Fuse | Circuit breaker | Fuse type Rated voltage 600В VВ AC |
|---|
В | В | В | Current | 3NA3 | 2NE1 | В | В | Current |
|---|
kW | hp | Type 6SL3210-... | Frame size | A | Article No. | Article No. | Article No. | Class | A |
|---|
Line voltage 380 ... 480 V 3 AC | 0.55 | 0.75 | 1KE11-8..2 | FSAA | 10 | 3NA3803 | – | 3RV2011-1JA10 | J, T, CC, G, CF | 10 | 0.75 | 1 | 1KE12-3..2 | 1.1 | 1.5 | 1KE13-2..2 | 1.5 | 2 | 1KE14-3..2 | 2.2 | 3 | 1KE15-8..2 | 3 | 4 | 1KE17-5..1 | FSA | 16 | 3NA3805 | – | 3RV2011-4AA10 | J, T, CC, G, CF | 15 | 4 | 5 | 1KE18-8..1 | 5.5 | 7.5 | 1KE21-3..1 | FSB | 32 | 3NA3812 | – | 3RV2021-4EA10 | J, T, CC, G, CF | 35 | 7.5 | 10 | 1KE21-7..1 | 11 | 15 | 1KE22-6..1 | FSC | 63 | 3NA3822 | – | 3RV1041-4JA10 | J, T, CC, G, CF | 60 | 15 | 20 | 1KE23-2..1 | 18.5 | 25 | 1KE23-8..1 | 22 | 30 | 1KE24-4.F1 | FSD | 80 | 3NA3824 | 3NE1820-0 | 3RV2031-4WA10 | J, T, CC, G, CF | 70 | 30 | 40 | 1KE26-0.F1 | FSD | 100 | 3NA3830 | 3NE1021-0 | 3RV1041-4LA10 | J, T, CC, G, CF | 90 | 37 | 50 | 1KE27-0.F1 | 3RV1041-4MA10 | J, T, CC, G, CF | 100 | 45 | 60 | 1KE28-4.F1 | FSD | 125 | 3NA3832 | 3NE1022-0 | – | J, T, CC, G, CF | 125 | 55 | 75 | 1KE31-1.F1 | FSE | 160 | 3NA3836 | 3NE1224-0 | – | J, T, CC, G, CF | 150 | 75 | 100 | 1KE31-4.F1 | FSF | 200 | 3NA3140 | 3NE1225-0 | – | J, T, CC, G, CF | 200 | 90 | 125 | 1KE31-7.F1 | FSF | 250 | 3NA3142 | 3NE1277-0 | – | J, T, CC, G, CF | 250 | 110 | 150 | 1KE32-1.F1 | FSF | 315 | 3NA3250 | 3NE1230-0 | – | J, T, CC, G, CF | 300 | 132 | 200 | 1KE32-4.F1 | FSF | 350 | 3NA3252 | 3NE1331-0 | – | J, T, CC, G, CF | 350 |
|
|