3RQ3018-2AE00Öåíà íà ñàéòå óêàçàíà ðîçíè÷íàÿ â ÅÂÐÎ áåç ó÷åòà ÍÄÑ. Äëÿ óòî÷íåíèÿ öåíû è ðàçìåðà ïðåäîñòàâëÿåìîé ñêèäêè - çâîíèòå èëè ïðèñûëàéòå çàÿâêè | Çàêàçíîé íîìåð | Âåñ | PG | Îïèñàíèå ïðîäóêòà | Öåíà | | 3RQ3018-2AE00 | 0.03 | 41H | OUTPUT COUPLING DEVICE, RELAY COUPLER, 1 CO CONTACT 115V AC/DC, WIDTH 6.2MM SPRING-TYPE TERMINALS (PUSH IN) | Ïî çàïðîñó |

SIRUS 3RQ3 coupling relays in slim design are used to connect control signals from and to a PLC, and they are available in different versions: - Coupling relays with relay output (not plug-in)
- Coupling relays with plug-in relay
- Coupling relays with semiconductor output (not plug-in)
Coupling relays with relay output (not plug-in)AC and DC operation IEC/EN 60947‑5‑1 The input and output coupling relays differ with regard to the positioning of the terminals and the LED. Coupling relays with plug-in relayAC and DC operation IEC 60947‑1 The coupling relays are plug-in, so the relay can be replaced quickly at the end of its service life without detaching the wiring. Coupling relays with semiconductor output (not plug-in)AC and DC operation IEC/EN 60947‑1, EN 60664‑1 and EN 50005; Coupling relays with semiconductor output: EN 60747‑5; programmable controllers: IEC 61131‑2 The input and output coupling relays differ with regard to the positioning of the terminals and the LEDs. The coupling relays with semiconductor output have extremely high contact reliability, so they are especially suitable for electronic systems. For test purposes, versions are available with manual-0-automatic switches. Spring-type terminals (push-in) with TOP wiringPush-in connections are a form of spring-type terminals allowing fast wiring without tools for rigid conductors or conductors equipped with end sleeves. As with other spring-type terminals, a screwdriver (with 3.0 x 0.5 mm blade) is required to disconnect the conductor. The same tool can also be used to wire finely-stranded or stranded conductors with no end finishing. The advantages of the push-in terminals are found, as with all spring-type terminals, in speed of assembly and disassembly and vibration-proof connection. There is no need for the checking and tightening required with screw terminals. With the TOP wiring method, the wire inlet and terminals can be reached from the front. This helps to speed up the wiring process and eliminate wiring errors. Article No. schemeProduct versions | Article number |
|---|
Coupling relays with relay output (not plug-in) | 3RQ30 | ⒠| 8 | – | ⒠| A | ⒠| 0 | ⒠|  | Design and output type | Output coupler Without manual/automatic switch |  | 1 |  |  |  |  |  |  |  |  | Input coupler |  | 3 |  |  |  |  |  |  |  |  | Type of electrical connection | Screw terminals |  |  |  |  | 1 |  |  |  |  |  | Spring-type terminals (push-in) |  |  |  |  | 2 |  |  |  |  |  | Control supply voltage | 24 V AC/DC |  |  |  |  |  |  | B |  |  |  | 115 V AC/DC |  |  |  |  |  |  | E |  |  |  | 230 V AC/DC |  |  |  |  |  |  | F |  |  |  | Material of switching contacts | e. g. |  |  |  |  |  |  |  |  |  |  | 0 = AgSnO2 |  |  |  |  |  |  |  |  | ⒠|  | 1 = AgSnO2 hard gold-plated |  |  |  |  |  |  |  |  | ⒠|  | Example |  | 3RQ30 | 1 | 8 | – | 1 | A | B | 0 | 1 |  |
Product versions | Article number |
|---|
Coupling relays with relay output (not plug-in) | 3RQ30 | 1 | 8 | – | 2 | A | ⒠| 0 | 8 | – | 0 | A | A | 0 |  | Railway version with extended operating range 0.7 ... 1.2 x U s |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Control supply voltage | 24 V DC |  |  |  |  |  |  | M |  |  |  |  |  |  |  |  | 110 V DC |  |  |  |  |  |  | N |  |  |  |  |  |  |  |  | Example |  | 3RQ30 | 1 | 8 | – | 2 | A | M | 0 | 8 | – | 0 | A | A | 0 |  |
Product versions | Article number |
|---|
Coupling relays with plug-in relay | 3RQ31 | 1 | 8 | – | ⒠| A | ⒠| 0 | ⒠|  | Type of electrical connection | Screw terminals |  |  |  |  | 1 |  |  |  |  |  | Spring-type terminals (push-in) |  |  |  |  | 2 |  |  |  |  |  | Control supply voltage | 24 V AC/DC |  |  |  |  |  |  | B |  |  |  | 115 V AC/DC |  |  |  |  |  |  | E |  |  |  | 230 V AC/DC |  |  |  |  |  |  | F |  |  |  | 24 V DC |  |  |  |  |  |  | M |  |  |  | Material of switching contacts | AgSnO2 |  |  |  |  |  |  |  |  | 0 |  | AgSnO2 hard gold-plated |  |  |  |  |  |  |  |  | 1 |  | Example |  | 3RQ31 | 1 | 8 | – | 1 | A | B | 0 | 1 |  |
Product versions | Article number |
|---|
Coupling relays with semiconductor output (not plug-in) | 3RQ30 | ⒠| ⒠| – | ⒠| S | ⒠| ⒠| 0 |  | |  | Current carrying capacity of the semiconductor output |  |  |  |  |  |  |  |  |  | Control supply voltage | Switching voltage of the semiconductor output | Output coupler |  |  |  |  |  |  |  |  |  |  |  |  | - Without manual/automatic switch
| 1 mA ... 0.5 A | 3RQ30 | 5 | 0 | – | ⒠| S | M | 5 | 0 | 11 ... 30 V DC | 10 ... 60 V DC | 5 mA ... 2 A | 3RQ30 | 5 | 2 | – | ⒠| S | M | 3 | 0 | 11 ... 30 V DC | 10 ... 30 V DC | 1 mA ... 2 A | 3RQ30 | 5 | 2 | – | ⒠| S | M | 4 | 0 | 11 ... 30 V DC | 10 ... 60 V DC | 5 mA ... 2 A | 3RQ30 | 5 | 2 | – | ⒠| S | M | 5 | 0 | 11 ... 30 V DC | 20 ... 264 V AC | 1 mA ... 3 A | 3RQ30 | 5 | 3 | – | ⒠| S | G | 3 | 0 | 110 ... 230 V AC/DC | 10 ... 30 V DC | 5 mA ... 5 A | 3RQ30 | 5 | 5 | – | ⒠| S | M | 3 | 0 | 11 ... 30 V DC | 10 ... 30 V DC | - With manual/automatic switch
| 5 mA ... 5 A | 3RQ30 | 6 | 5 | – | ⒠| S | M | 3 | 0 | 11 ... 30 V DC | 10 ... 30 V DC | Input coupler | 10 mA ... 0.5 A | 3RQ30 | 7 | 0 | – | ⒠| S | B | 3 | 0 | 11 ... 30 V AC/DC | 10 ... 30 V DC | 3RQ30 | 7 | 0 | – | ⒠| S | G | 3 | 0 | 110 ... 230 V AC/DC | 10 ... 30 V DC | Type of electrical connection | Screw terminals Spring-type terminals (push-in) |  |  |  |  | 1 2 |  |  |  |  |  |  | Example |  | 3RQ30 | 7 | 0 | – | 1 | S | B | 3 | 0 |  |  |
Note: These Article No. schemes show an overview of product versions for better understanding of the logic behind the article numbers. For your orders please use the article numbers quoted in the selection and ordering data.
|