3NA3252Цена на сайте указана розничная в ЕВРО без учета НДС. Для уточнения цены и размера предоставляемой скидки - звоните или присылайте заявки | Заказной номер | Вес | PG | Описание продукта | Цена | | 3NA3252 | 0.66 | 1BM | ПЛАВКАЯ ВСТАВКА НИЗКОВОЛЬТНАЯ GL/GG С НЕИЗОЛИРОВАННЫМИ ВЫСТУПАМИ ДЛЯ МОНТ./ДЕМОНТ. ТИПОРАЗМЕР 2, Iном.=315A, Uном.=500В | По запросу |
Selection and ordering dataThe following table lists recommendations for additional line-side components, such as fuses and circuit breakers. The values in the table take into account the overload capability of the inverter. Notes for use in compliance with IEC standards: 3NA3 or 3NE1 fuses and 3RV or 3VL circuit breakers are recommended for European countries. Notes for use in compliance with UL regulations: UL-listed fuses Class J or 3NE1 with 600 V AC rated voltage (UL-compliant – corresponds to RU) are required for North America. Short-Circuit Current Rating SCCR (Short-Circuit Current Rating) according to UL Applies to industrial control panel installations acc. to NEC article 409 or UL 61800-5-1. Notes regarding installations in Canada: Overvoltage protection devices in accordance with overvoltage category III and with the following ratings must be connected on the line side of the inverter: - Rated voltage 480 V/600 V (phase-phase), 480 V/600 V (phase-ground) at a rated line voltage of 480 V/600 V
- Voltage limit 4В kV (phase-phase) and 6 kV (phase-ground)
All overvoltage protection devices used must comply with Canadian standards for industrial installations. Additional information about the listed fuses and circuit breakers is available in Catalogs LVВ 10, ICВ 10 and ICВ 10В AO. Rated power 1) | SINAMICSВ G120, PM240P-2 Power Modules | IEC-compliant | UL/cUL-compliant |
|---|
В | В | В | В | Fuse | Circuit breaker | Fuse | Fuse type Rated voltage 600В VВ AC |
|---|
400В V/690В V | 460В V/575В V | Type | В | Current | Type 3NA3 | В | Type 3NE1 (RU) | В | Current |
|---|
kW | hp | 6SL3210-... | Frame size | A | Article No. | Article No. | Article No. | Class | A |
|---|
380 ... 480 V 3 AC | 22 | 25 | 1RE24-5 . L0 | FSD | 80 | 3NA3824 | 3RV1041-4KA10 | 3NE1820-0 | J | 70 | 30 | 30 | 1RE26-0 . L0 | FSD | 100 | 3NA3830 | 3RV1041-4LA10 | 3NE1021-0 | J | 90 | 37 | 40 | 1RE27-5 . L0 | FSD | 100 | 3NA3830 | 3RV1041-4MA10 | 3NE1021-0 | J | 100 | 45 | 50 | 1RE28-8 . L0 | FSE | 125 | 3NA3832 | 3VL1712-2DD33-…. *) | 3NE1022-0 | J | 125 | 55 | 60 | 1RE31-1 . L0 | FSE | 160 | 3NA3836 | 3VL1716-2DD33-…. *) | 3NE1224-0 | J | 150 | 75 | 75 | 1RE31-5 . L0 | FSF | 200 | 3NA3140 | 3VL3720-3DC33-…. *) | 3NE1225-0 | J | 200 | 90 | 100 | 1RE31-8 . L0 | FSF | 224 | 3NA3142 | 3VL3725-3DC33-…. *) | 3NE1227-0 | J | 225 | 110 | 125 | 1RE32-1 . L0 | FSF | 300 | 3NA3250 | 3VL4731-3DC36-…. *) | 3NE1230-0 | J | 300 | 132 | 150 | 1RE32-5 . L0 | FSF | 315 | 3NA3252 | 3VL4740-3DC36-…. *) | 3NE1331-0 | J | 350 | 500 ... 690 V 3 AC | 11 | 10 | 1RH21-4 . L0 | FSD | 50 | 3NA3120-6 | 3RV1042-4BA10 | 3NE1815-0 | J | 20 | 15 | 15 | 1RH22-0 . L0 | FSD | 50 | 3NA3120-6 | 3RV1042-4EA10 | 3NE1815-0 | J | 25 | 18.5 | 20 | 1RH22-3 . L0 | FSD | 50 | 3NA3120-6 | 3RV1042-4EA10 | 3NE1803-0 | J | 30 | 22 | 25 | 1RH22-7 . L0 | FSD | 50 | 3NA3120-6 | 3VL1704-2DD33-…. *) | 3NE1803-0 | J | 35 | 30 | 30 | 1RH23-5 . L0 | FSD | 50 | 3NA3120-6 | 3VL1705-2DD33-…. *) | 3NE1817-0 | J | 45 | 37 | 40 | 1RH24-2 . L0 | FSD | 63 | 3NA3122-6 | 3VL1706-2DD33-…. *) | 3NE1818-0 | J | 60 | 45 | 50 | 1RH25-2 . L0 | FSE | 80 | 3NA3124-6 | 3VL1708-2DD33-…. *) | 3NE1820-0 | J | 80 | 55 | 60 | 1RH26-2 . L0 | FSE | 80 | 3NA3124-6 | 3VL1710-2DD33-…. *) | 3NE1820-0 | J | 80 | 75 | 75 | 1RH28-0 . L0 | FSF | 100 | 3NA3130-6 | 3VL1712-2DD33-…. *) | 3NE1021-0 | J | 100 | 90 | 100 | 1RH31-0 . L0 | FSF | 125 | 3NA3132-6 | 3VL1712-2DD33-…. *) | 3NE1022-0 | J | 125 | 110 | 100 | 1RH31-2 . L0 | FSF | 160 | 3NA3136-6 | 3VL1716-2DD33-…. *) | 3NE1224-0 | J | 150 | 132 | 125 | 1RH31-4 . L0 | FSF | 200 | 3NA3140-6 | 3VL3720-3DC33-…. *) | 3NE1225-0 | J | 200 |
1) Rated power based on the rated output current Irated. The rated output current Irated is based on the duty cycle for low overload (LO). *) See Catalog LVВ 10 for Article No. supplements.
|